Enter/Exit Programming Mode

Interleaved 2 of 5 (I 2 of 5)

126

WDI4600

I 2 of 5 Set Length 2

This feature specifies one of the barcode lengths for

I 2 of 5 Length Control

. Length 2 is the

maximum label length if in

Variable Length

Mode, or the second fixed length if in

Fixed Length

Mode. The length includes the barcode’s check and data characters.

The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only
one fixed length).

Table 8

provides examples for setting Length 2. See

page 217

for detailed instructions on setting

this feature.

Table 8. I 2 of 5 Length 2 Setting Examples

STEP

ACTION

EXAMPLES

1

Desired Setting

Ignore This

Length

4 Characters

14 Characters

50 Characters

2

Pad with leading zeroes to

yield two digits

00

04

14

50

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT I 2 OF 5 LENGTH 2 SETTING

5

Scan Two Characters From

Appendix D, Keypad

‘0’ and ‘0’

‘0’ and ‘4’

‘1’ and ‘4’

‘5’ AND ‘0’

6

Scan ENTER/EXIT PROGRAMMING MODE

$CI2L2

Select I 2 of 5 Length 2 Setting

Make a mistake? Scan the CANCEL barcode to abort and
not save the entry string. You can then start again at the
beginning.

~

CANCEL

DEFAULT

50 = Length 2 is 50 Characters