Flash on time – Wasp Barcode WDI4600 2D Product Reference Guide User Manual

Page 242

Advertising
background image

References

232

WDI4600

Flash On Time

This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable
range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments.

Follow these instructions to set this feature.

1. Determine the desired setting in milliseconds.

2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with

leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.

3. Go to

page 70

and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter

Programming Mode.

4. Scan the barcode: SELECT FLASH ON TIME SETTING.

5. Scan the appropriate two digits from the keypad in

Appendix D, Keypad

representing the

duration which was determined in the steps above. You will hear a two-beep indication
after the last character.

If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the begin-
ning.

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming

Mode.

This completes the procedure. See

Table 41

for examples of how to set this feature.

Table 41. Flash On Time Setting Examples

STEP

ACTION

EXAMPLES

1

Desired Setting

500ms

1,000ms (1 sec.)

5200ms (5.2 sec.)

9,900ms (9.9 sec.)

2

Divide by 100 (and pad with

leading zeroes to yield two

digits)

05

10

52

99

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT FLASH ON TIME SETTING

5

Scan Two Characters From

Appendix D, Keypad

‘0’ and ‘5’

‘1’ and ‘0’

‘5’ and ‘2’

‘9’ and ‘9’

6

Scan ENTER/EXIT PROGRAMMING MODE

Advertising