Ack nak retry count – Wasp Barcode WDI4600 2D Product Reference Guide User Manual

Page 221

Advertising
background image

RS-232 Parameters

Product Reference Guide

211

ACK NAK Retry Count

This feature specifies the number of times the reader retries a label transmission due to a retry
condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and
a selection of 255 specifies unlimited retries.

To set this feature:

1. Determine the desired setting.

2. Pad the number with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005,

20 = 020, etc.

3. Go to

page 28

and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter

Programming Mode.

4. Scan the barcode: SELECT ACK NAK RETRY COUNT SETTING.

5. Scan the appropriate three digits from the keypad in

Appendix D, Keypad

, that represent

the number which was determined in the steps above. You will hear a two-beep indication
after the last character.

If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the begin-
ning.

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming

Mode.

This completes the procedure. See

Table 29

for some examples of how to set this feature.

Table 29. ACK NAK Retry Count Setting Examples

STEP

ACTION

EXAMPLES

1

Desired Setting

Disable Retry

Count

3 Retries

54 Retries

Unlimited Retries

2

Pad with leading zero(es)

000

003

054

255

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT ACK NAK RETRY COUNT SETTING

5

Scan Three Characters From

Appendix D, Keypad

‘0’, ‘0’ and ‘0’

‘0’, ‘0’ and ‘3’

‘0’, ‘5’ and ‘4’

‘2’, ‘5’ and ‘5’

6

Scan ENTER/EXIT PROGRAMMING MODE

Advertising