Enter/Exit Programming Mode

Industrial 2 of 5

134

WDI4600

Industrial 2 of 5 Set Length 1

This feature specifies one of the barcode lengths for

Industrial 2 of 5 Length Control

. Length 1

is the minimum label length if in

Variable Length

Mode, or the first fixed length if in

Fixed

Length

Mode. Length includes the barcode’s data characters only. The length can be set from 0

to 50 characters.

Table 11

provides some examples for setting Length 1. See

page 217

if you want detailed

instructions on setting this feature.

Table 11. Industrial 2 of 5 Length 1 Setting Examples

STEP

ACTION

EXAMPLES

1

Desired Setting

00 Characters

07 Characters

15 Characters

50 Characters

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT INDUSTRIAL 2 OF 5 LENGTH 1 SETTING

4

Scan Two Characters From

Appendix D, Keypad

‘0’ and ‘0’

‘0’ and ‘7’

‘1’ and ‘5’

‘5’ AND ‘0’

5

Scan ENTER/EXIT PROGRAMMING MODE

$CU2L1

Select Industrial 2 of 5 Set Length 1 Setting

Make a mistake? Scan the CANCEL barcode to abort and
not save the entry string. You can then start again at the
beginning.

~

CANCEL

DEFAULT

01 = Length 1 is 1 Character

Advertising