Code 11 set length 2, Default – Wasp Barcode WDI4600 2D Product Reference Guide User Manual

Page 159

Advertising
background image

Code 11

Enter/Exit Programming Mode

Product Reference Guide

149

Code 11 Set Length 2

This feature specifies one of the barcode lengths for

Code 11 Length Control

. Length 2 is the

maximum label length if in

Variable Length

Mode, or the second fixed length if in

Fixed Length

Mode. Length includes the barcode’s check and data characters.

The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only
one fixed length).

Table 16

provides examples for setting Length 2. See

page 217

for detailed instructions on

setting this feature.

Table 16. Code 11 Length 2 Setting Examples

STEP

ACTION

EXAMPLES

1

Desired Setting (pad with

leading zeroes)

00 (Ignore This

Length)

07 Characters

15 Characters

50 Characters

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT CODE 11 LENGTH 2 SETTING

4

Scan Two Characters From

Appendix D, Keypad

‘0’ and ‘0’

‘0’ and ‘7’

‘1’ and ‘5’

‘5’ and 0’

5

Scan ENTER/EXIT PROGRAMMING MODE

$CC1.2

Select Code 11 Length 2 Setting

Make a mistake? Scan the CANCEL barcode to abort and
not save the entry string. You can then start again at the
beginning.

~

CANCEL

DEFAULT

50 = Length 2 is 50 Characters

Advertising