Maxicode length control, Maxicode set length 1, Default – Wasp Barcode WDI4600 2D Product Reference Guide User Manual

Page 194: Maxicode, Set length 1

Advertising
background image

Enter/Exit Programming Mode

Maxicode

184

WDI4600

Maxicode Length Control

This feature specifies either variable length decoding or fixed length decoding for this
symbology.

Variable Length:

For variable length decoding, a minimum and maximum length may be set.

Fixed Length:

For fixed length decoding, two different lengths may be set.

DEFAULT

$CMXLC00(CR)

Maxicode Length Control = Variable Length

$CMXLC01(CR)

Maxicode Length Control = Fixed Length

Maxicode

Set Length 1

Specifies one of the barcode lengths for

Maxicode Length Control

. Length 1 is the minimum

label length if in

Variable Length

Mode, or the first fixed length if in Fixed Length Mode.

Characters can be set from 0001 to 0145 characters in increments of 0001 (pad with zeroes).

See

page 217

for detailed instructions on setting this feature.

$CMXL1

Select Maxicode Length 1 Setting

To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE barcode above, then the barcode at
left followed by the digits from the Alphanumeric char-
acters in

Appendix D, Keypad

representing your

desired character(s). End by scanning the ENTER/EXIT
barcode again.

Make a mistake? Scan the CANCEL barcode to abort and
not save the entry string. You can then start again at the
beginning.

~

CANCEL

DEFAULT

0001 = Length 1 is 1 Character