Technical Specifications

244

WDI4600

Table 49

Programming Mode

- The following indications ONLY occur when the reader is in Programming Mode.

Label Program-
ming Mode Entry

A valid programming label has
been scanned.

LED blinks continuously

Reader sounds four low fre-

quency beeps.

Label Program-
ming Mode
Rejection of Label

A label has been rejected.

N/A

Reader sounds three times at
lowest frequency & current vol-
ume.

Label Program-
ming Mode
Acceptance of
Partial Label

In cases where multiple labels
must be scanned to program one
feature, this indication acknowl-
edges each portion as it is suc-
cessfully scanned.

N/A

Reader sounds one short beep

at highest frequency & current

volume.

Label Program-
ming Mode
Acceptance of
Programming

Configuration option(s) have
been successfully programmed
via labels and the reader has
exited Programming Mode.

N/A

Reader sounds one high fre-
quency beep and 4 low fre-
quency beeps followed by reset
beeps.

Label Program-
ming Mode Can-
cel Item Entry

Cancel label has been scanned.

N/A

Reader sounds two times at low
frequency and current volume.

. Programming Mode Indications

Error Codes

Upon startup, if the reader sounds a long tone, this means the reader has not passed its
automatic Selftest and has entered FRU (Field Replaceable Unit) isolation mode. If the reader is
reset, the sequence will be repeated. The following table describes the LED flashes/beep codes
associated with an error found.

NUMBER OF LED

FLASHES/BEEPS

ERROR

CORRECTIVE ACTION

1

Configuration

Contact Helpdesk for assis-

tance

2

Interface PCB

6

Digital PCB

12

Imager

15

Accelerometer