Plessey set length 2, Default – Wasp Barcode WDI4600 2D Product Reference Guide User Manual

Page 180

Advertising
background image

Enter/Exit Programming Mode

Plessey

170

WDI4600

Plessey Set Length 2

This feature specifies one of the barcode lengths for

Plessey Length Control

. Length 2 is the

maximum label length if in

Variable Length

Mode, or the second fixed length if in

Fixed Length

Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length
does not include start/stop characters.

The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only
one fixed length).

Table 24

provides examples for setting Length 2. See

page 217

for detailed instructions on

setting this feature.

Table 24. Plessey Length 2 Setting Examples

STEP

ACTION

EXAMPLES

1

Desired Setting

00 (Ignore This

Length)

07 Characters

15 Characters

50 Characters

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT PLESSEY LENGTH 2 SETTING

4

Scan Two Characters From

Appendix D, Keypad

‘0’ and ‘0’

‘0’ and ‘7’

‘1’ and ‘5’

‘5’ AND ‘0’

5

Scan ENTER/EXIT PROGRAMMING MODE

$CPLL2

Select Plessey Length 2 Setting

Make a mistake? Scan the CANCEL barcode to abort and
not save the entry string. You can then start again at the
beginning.

~

CANCEL

DEFAULT

50 = Length 2 is 50 Characters

Advertising