Conventions used in this manual – Rockwell Automation 160 AC DRIVE SER B/FRN 5-6.XX User Manual

Page 13

Advertising
background image

Chapter 1 – Information and Precautions

1-2

Figure 1.1 – Catalog Number Code Explanation

160 – A A04 N SF1 P1

Bulletin
Number

Current
Rating

Enclosure
Type

Voltage Rating

A01
A02
A03
A04
A06
A08
A12

Letter Type
N Open (IP20)
P Chassis Mount

(external
heatsink)

A 200 – 240V 1

200 – 240V 3

B 380 – 460V 3

First
Position

Second
Position

Third
Position

Fourth
Position

Sixth
Position

Control

Fifth
Position

Programmer
(Optional)

SF1 = Analog

Signal
Follower

PS1 = Preset

Speed

Program
Keypad Module

An “S” in the
Bulletin Number
denotes a single
phase input
voltage.

This manual applies only to the open style (IP20) device. Refer to separate instruction sheets for Chassis Mount
and NEMA 4 (IP66) devices.

Figure 1.2 – Nameplate Information

CAT160–AA04NSF1P1

SER B

I

N
P
U

T

V:

A:

Hz:

VA:

O
U

T
P

U

T

V:

A:

Hz:

3

Motor
Rating:

200-240
5.4
50/60
2200

200-230
4.5
0-240

0.75kW/1HP

ALLEN-BRADLEY

MADE IN U.S.A.

Nameplate is located on the
side of the unit.

3

ОО

ОО

ОО

ОО

О

О

О

О

S/N 32098

IP20

OPERATING AMBIENT TEMP: 0 – 50

°

C

SHORT CIRCUIT CURRENT: 10KA
POWER TERMINAL WIRE: Use 75

°

C Cu Wire

4mm

2

– .75mm

2

(12 – 18 AWG.)

Torque 1.35 Nm (12 in.-lbs.)

WARNING: ! Allow 1 Minute after power is removed
before servicing. Accessible surfaces may be hot.
Compatible with Type B RCD protection devices only.

FRN:

6.xx

Conventions Used In This Manual

Parameter numbers and names are shown in bold typeface and follow the format PXX – [*] where P
denotes parameter, XX denotes the two digit parameter number, and * represents the parameter name. For
example, P01 – [Output Frequency].

Advertising