4–45

1336 FORCE — 5.9 August 1995

PARAMETERS

DATA TYPE

LINKABLE

DEFAULT VALUE

RANGE

Lim In

Signed Integer

Yes

0

±

32767

Lim Set

Logic Input

Yes

0

True/False

Lim Data

Signed Integer

Yes

0

±

32767

Lim Rate

Unsigned Integer

No

0

0 to 65535

Lim @ Lim

Logic Output

No

True/False

Lim Out

Signed Integer

No

±

32767

Lim @Lim = True

Time

Example 1

+ 32767

0

– 32767

Lim @Lim = False

When Lim Rate = 65535, t1 = 1 sec

When Lim Rate = 32767, t1 = 2 sec

Lim In
Lim Out

t1