4–53

1336 FORCE — 5.9 August 1995

OUTPUTS

Dir — A signed integer that indicates counter direction —
–1 if decrementing, 0 if no change, 1 if incrementing.

@Hi Lim — A logic value = true only when the accumulator >
Max.

@Lo Lim — A logic value = true only when the accumulator <
Min.

Output — A signed integer that is the counter’s output.

FUNCTION

1. If Set

0, the accumulator = Preset.

2. When Select = 0 and Time = time since last adjustment of

accumulator:
If Inc

0, the accumulator = accumulator + UD1, and Dir = 1.

If Dec

0, The accumulator = accumulator – UD1, and Dir = –1.

3. When Select

0 and Time = time since last adjustment of

accumulator:
If Inc

0, the accumulator = accumulator + UD2, and Dir = 1

If Dec

0, The accumulator = accumulator – UD2, and Dir = –1.

4. When the accumulator > Max:

The accumulator = Max, @Hi Lim = true, and @Lo Lim = false.

5. When the accumulator < Min:

The accumulator = Min, @Hi Lim = false, and @Lo Lim = true.

6. When the accumulator is < Max and > Min:

@Lo Lim = @Hi Lim = false.

7. When Output = accumulator, Dir = 0.

PARAMETERS

DATA TYPE

LINKABLE

DEFAULT VALUE

RANGE

Set

Logic Input

Yes

False

True/False

Inc

Logic Input

Yes

False

True/False

Dec

Logic Input

Yes

False

True/False

Max

Signed Integer

No

0

±

32767

Min

Signed Integer

No

0

±

32767

UD1

Signed Integer

No

0

0 to + 32767

UD2

Signed Integer

No

0

0 to + 32767

Select

Logic Input

No

False

True/False

Preset

Signed Integer

No

0

±

32767

Time

Unsigned Integer

No

0

0 to 65535

Dir

Signed Integer

No

±

32767

@Hi Lim

Logic Input

No

True/False

@Lo Lim

Logic Input

No

True/False

Output

Signed Integer

No

±

32767