5–38

Block Transfer Services

1336 FORCE — 5.9 August 1995

The Read Full Node Information message provides all known
attributes for any node in the current application. This information
includes the node’s current value, descriptor, multiply and divide
value, base value, offset value, text string, file group and element
reference, minimum value, maximum value, and default value.

PLC Block Transfer Instruction Data

BTW Instruction Length:

3 Words

BTR Instruction Length:

22 Words

0

Header

Word 1

Header

Word 1

Node ID

0F00

Node Number

Message Structure

Header

Word 2

Data

Word 3

Header

Word 2

Data

Word 3

PLC Request –– Block Transfer Write

Drive Response –– Block Transfer Read

Data

Word 4

Descriptor

1

Data

Word 5

Data

Word 6

1

Data

Word 8

0

0F00 –– Message OK

8F00 –– Message Error

Current Value

1

Data

Word 7

0

Node Text

Data

Word 9

Data

Word 10

Character 2

Character 1

Node Text

Data

Word 11

Character 4

Character 3

Node Text

Data

Word 12

Character 6

Character 5

Node Text

Data

Word 13

Character 8

Character 7

Node Text

Data

Word 14

Character 10

Character 9

8NID

where:

N = the node number

ID = the block ID number

Note: If N is 16, the node

number becomes 90ID.

8NID

Node Adjustment:

Read Full Node Information

Advertising