Function Block Library

4–52

1336 FORCE — 5.9 August 1995

UP/DWN CNTR

BLOCK TYPE 24 decimal 18 hexadecimal

Up/Down Counter

ID =

Exec =

NODE 0

Set

NODE 1

@Hi Lim

NODE 11

Dir

NODE 10

Output

NODE 13

@Lo Lim

NODE 12

Inc

NODE 2

Dec

NODE 3

Max

NODE 4

Min

NODE 5

UD1

NODE 6

UD2

NODE 7

Select

NODE 8

Preset

NODE 9

Time

UD1

UD2

t

DEFINITION

An up/down counter function block that can be programmed to count
up or down in a specified, programmable time period.

INPUTS

Set — A logic signal that when

0 sets the counter output to the

value of Preset.

Inc — A logical word that specifies the counter is to increment the
accumulator.

Dec — A logical word that specifies the counter is to decrement the
accumulator.

Max — A signed integer that limits the upper value of the output.

Min — A signed integer that limits the lower value of the output.

UD1 — An signed integer that together with Time determines
the Inc/Dec rate.

UD2 — A signed integer that together with Time determines the
Inc/Dec rate.

Select — An input word value if = 0 selects UD1, if

0 selects

UD2.

Preset — A signed integer that can be preloaded into the output if
Set

0.

Time — An unsigned word that determines the period where the

UD1/UD2 increment is to be added or subtracted from the
accumulator counter value. The Time value is entered in
mS, with a resolution limited by the task interval —
(Time in) / 20mS.

Advertising