1–13

Getting Started

1336 FORCE — 5.9 August 1995

2. Enter an offset value of

0

for Parameters

400

and

404

. This

allows a value of

±

32767 to traverse the entire

±

10V range for

both analog outputs.

3. Within the link window at the bottom of the screen, double click

on the Par # field associated with Parameter 387.

Link analog output #1, Parameter 387, to Rate Limiter output
node Output (4:5).

The window shown below should appear with entry boxes.

4. Enter a

Task Number

of

1

.

Enter a

Block Number

of

4

.

Enter a

Node Number

of

5

.

Click on

OK

.

Link analog output #3, Parameter 389, to Rate Limiter input node
Input 1 (4:0).