Rockwell Automation 1336T Function Block Prog. Manual, Series A/B User Manual
Page 21
1–9
Getting Started
1336 FORCE — 5.9 August 1995
Step 4 — Enter a Rate Limit Block
To add a Rate Limit function block:
1. Move the cursor to the left side of the execution list and click.
2. Select the
Add Block
option from the
Function Blocks
pull-down menu.
3. Double click on
Rate Limiter — [Lib ID: 19
].
4. Click on
CLOSE
.
As shown below, the DriveBlockEditor software now enters a Rate
Limiter function block and gives it an
ID #
of
4
.
5. Enter a value for the rate by clicking in the
Value
field for
Node
3
and entering
65535
.
Press enter to save the value as shown below.
You can now link the Rate Limiter input to the output of the
Multiplexer function block entered in
Step 3
.
6. Link the Rate Limiter’s input (node 0), to the Multiplexer’s
output (node 6).
Click on the
Link To
field for
Node 0
and enter
3:6
.