Operating modes, Counter mode – Rockwell Automation 1734-VHSC24 Very High-Speed Counter Modules User Manual User Manual

Page 12

Advertising
background image

Publication 1734-UM003B-EN-P - August 2005

1-2 About the Modules

The outputs are rated to source 0.5A at 10 to 28.8V dc. The output
may be tied to an input. This lets you cascade counters of multiple
1734-VHSC modules. The counter has 4 user-selectable On-Off values
(windows) associated with it. Tie either output to any or all of the
window signals.

Operating Modes

The modules operate in the modes shown in the table.

The operation of the counter and encoder modes is nearly identical.
The difference between the two modes is in the type of feedback
(single-phase versus two-phase) for the count direction (up or down).
In encoder mode, a transition is expected on the B input for
counting to proceed in a direction; whereas, in counter mode, the B
input may be left at a static level.

You select all operating modes by writing appropriate configuration
data to the module.

Counter Mode

The counter mode reads incoming pulses and returns a binary
number (0 - 16,777,215

max

) to the POINTBus. The counter mode only

accepts single-phase inputs. The module determines the Phase B
input state, and counts up or down accordingly.

Mode

Description

Counter Mode

Read read incoming single-phase pulses, return a
binary count.

Encoder Mode

Read incoming two-phase quadrature pulses, return
a binary count.

Period/Rate Mode

Count internal clocks during the On period, return a
frequency. Outputs updated only at the end of the
period.

Continuous/Rate Mode

Count internal clocks during the On period, return a
frequency. Outputs are updated continuously during
the period.

Rate Measurement Mode

Read pulses during the sample period, return a
frequency.

PWM Mode (pulse width
modulation)

Generate a pulse width modulated signal.

Advertising
This manual is related to the following products: