Output control, Store-reset/start, On-off operation of output 0 – Rockwell Automation 1734-VHSC24 Very High-Speed Counter Modules User Manual User Manual

Page 22

Advertising
background image

Publication 1734-UM003B-EN-P - August 2005

1-12 About the Modules

Store-Reset/Start

Output Control

To connect an output to a compare window, you could program the
module accordingly:

• Tie Output 0 to Window 0
• Program Window 0 ON Value to 2000
• Program Window 0 OFF Value to 5000

ON-OFF Operation of Output 0

If the OFF value is greater than the ON value, the output turns ON at
2000 and OFF at 5000. If the ON value is greater than the OFF value,
the output turns OFF at 2000 and ON at 5000.

and Reset to zero

Start Counting

Continue Counting

Store Count,

Output turns ON at count value of 2000

Output turns OFF at count value of 5000

Output remains energized for 3000 additional counts

Effect of ON-OFF Value on Output Operation

Output turns ON

Output turns OFF

Output remains Energized

at count of 2000

for 3000 additional counts

at count of 5000

Turn Off Value > Turn On Value

Output turns OFF

Output turns ON

Output remains Deenergized

at count of 2000

for 3000 additional counts

at count of 5000

Turn On Value > Turn Off Value