Rockwell Automation 1747-BSN Backup Scanner Module User Manual

Page 173

Advertising
background image

Publication 1747-UM010B-EN-P - September 2003

Specifications A-9

The total increase in the RIO scan time (T

btx

)

is equal to:

T

btx

= sum of T

ri

for all logical racks

Example Discrete I/O Throughput with Block Transfers Present

An SLC 5/03 is using a backup scanner to control a 115.2K baud RIO
link that has 3 adapters and 4 logical devices.

Adapter #1 (1747-ASB module):

starting logical rack 0, logical group 0

12 logical groups (1 1/2 logical racks)

one 8 word and two 4 word BT write/read modules in logical
rack 0

one 2 word BT write/read module in logical rack 1

Adapter #2 (1771-ASB module):

starting logical rack 2, logical group 0

2 logical groups (1/4 logical rack)

one 64 word BT write/read module

Adapter #3 (1771-ASB module):

starting logical rack 2, logical group 2

2 logical groups (1/4 logical rack)

one 32 word BT write/read module