1-14 Overview

1/2-Slot Addressing

The figure below illustrates a possible module placement to configure
complementary I/O using 1/2-slot addressing.

I

(1)

01

23

45

67

01

23

I

I

O

O

O

O

BT

I

45

67

01

23

O

O

I

I

I

I

I

I

I

O

O

I

I

I

I

I

I

I

I

O

O

O

O

O

O

O

O

01

23

45

67

01

23

45

67

01

23

O

O

O

E

M

P
T
Y

I = Input Module (8-, 16-, or 32-point)
O = Output Module (8-, 16-, or 32-point)
BT = Block Transfer Module

(1) Must be empty if corresponding primary slot is a block transfer module.

Primary

Complementary

Primary

Complementary