Rockwell Automation 1747-BSN Backup Scanner Module User Manual

Page 91

Advertising
background image

Publication 1747-UM010B-EN-P - September 2003

Configuration and Programming 5-29

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

1

1

x

x

x

x

x

x

x

x

x

x

x

x

x

x

1

0

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

1

1

0

0

1

0

0

0

0

1

0

0

0

1

0

0

1

0

0

1

1

1

1

1

0

1

1

0

0

1

1

1

1

0

0

1

1

0

0

0

0

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

1

1

1

0

1

1

0

0

1

0

0

0

0

1

0

0

0

1

0

0

1

0

0

1

1

1

1

1

0

1

1

0

0

1

1

1

0

2

4

6

0

2

4

6

0

2

4

6

0

2

4

6

M1 (Status) File Primary/Normal

RIO Logical Rack 3 RIO Logical Rack 2

RIO Logical Rack 1

RIO Logical Rack 0

e = slot number of the SLC rack containing the scanner x =
not used/defined

G File

RIO Logical Rack 3
Starting Group

RIO Logical Rack 2
Starting Group

RIO Logical Rack 1
Starting Group

RIO Logical Rack 0
Starting Group

Primary Device Address, Word 8
Primary Device Size, Word 9
Primary Active Device Status, Word 10

M1:e.3
M1:e.4
M1:e.5

Logical Rack 0 Device Fault Status Word 12
Logical Rack 1 Device Fault Status Word 13
Logical Rack 2 Device Fault Status Word 14
Logical Rack 3 Device Fault Status Word 15

M1:e.12
M1:e.13
M1:e.14
M1:e.15

Status Word, Word 0

Baud Rate, Word 2

Primary Logical Device Address, Word 1
Primary Logical Image Size, Word 2

M1 File
M1:e.0

M1:e.2

Bit Number (decimal)

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

1

1

x

x

x

x

x

x

x

x

x

x

x

x

x

x

1

0

x

x

x

x

x

x

x

x

x

x

x

x

x

x

0

0

0

0

x

x

x

x

x

x

x

x

0

0

0

0

x

x

x

x

x

x

x

x

0

0

0

0

x

x

x

x

x

x

x

x

0

1

1

1

x

x

x

x

x

x

x

x

1

1

0

0

1

0

0

0

0

1

0

0

0

1

0

0

1

0

0

1

1

1

1

1

0

1

1

0

0

1

1

1

1

0

0

1

1

0

0

0

0

1

0

0

0

0

0

0

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

1

1

0

0

1

0

0

0

0

1

0

0

0

1

0

0

1

0

0

1

1

1

1

1

0

1

1

0

0

1

1

1

0

2

4

6

0

2

4

6

0

2

4

6

0

2

4

6

M1 (Status) File Complementary

RIO Logical Rack 11

RIO Logical Rack 10

RIO Logical Rack 9

RIO Logical Rack 8

e = slot number of the SLC rack containing the scanner x = not used/defined

G File

RIO Logical Rack 11
Starting Group

RIO Logical Rack 10
Starting Group

RIO Logical Rack 9
Starting Group

RIO Logical Rack 8
Starting Group

Primary Device Address, Word 3
Primary Device Size, Word 4
Primary Active Device Status, Word 5

M1:e.3
M1:e.4
M1:e.5

Logical Rack 0 Device Fault Status Word 12
Logical Rack 1 Device Fault Status Word 13
Logical Rack 2 Device Fault Status Word 14
Logical Rack 3 Device Fault Status Word 15

M1:e.12
M1:e.13
M1:e.14
M1:e.15

Status Word, Word 0

Baud Rate, Word 2

Complementary Logical Device Address, Word 3
Complementary Logical Image Size, Word 4

M1 File
M1:e.0

M1:e.2

Bit Number (decimal)

IMPORTANT

Individual quarter logical racks within a device
cannot be faulted. Therefore, only the starting logical
group of the device needs to be monitored.