D-2 Frequently Asked Questions

Q: Can I connect all of my outputs to the same output device?

A: Any or all of the 4 module outputs can go to the same output

device, as long as the output commons and Vcc are the same and
the total output current is less than 1.5 A.

Q: Can I connect all of my inputs to the same input device?

A: You can if the device supplies enough current to drive multiple

inputs.

Q: How does the module make rate calculations?

A: See Rate Value on page 2-10.

Q: How do I know what length to make my block transfer read/write

(BTR/BTW) file?

A: The BTR/BTW blocks should always consist of 8 input/output

words.