Module Operation 2-5

Figure 2.4 Quadrature Encoder Configurations

Input Frequency

Input frequency is determined by the input configuration as shown in
the table below.

12

11

10

9

8

7

6

5

4

3

2

1

2

3

4

5

6

7

8

9

10

1

0

6

5

4

3

2

1

1

0

2

3

4

5

1

2

3

1

0

2

11

Quadrature

Encoder

Input A

A

Forward Rotation

Input B

Input Z

B

Z

Reverse Rotation

A

B

X1 Count

X2 Count

X4 Count

IMPORTANT

The input configuration is limited by the operating
mode. In mode 1, Counters 1 and 2 can be assigned
any input configuration. In mode 2, Counter 1 can
be assigned any configuration, but Counters 2 and 3
are configured as pulse/internal direction. In mode
3, all counters have the pulse/internal direction
configuration. See the Summary of Available Counter
Configurations on page 2-8.

Input Configuration

Input Frequency

X4 Quadrature Encoder

250 kHz

X2 Quadrature Encoder

500 kHz

All Other Configurations

1 MHz

IMPORTANT

The minimum high and low times for the pulse train
are 475 ns. Therefore, the input pulse train must fall
between a 47.5 to 52.5 percent duty cycle at 1 MHz.