Rockwell Automation 1746-HSCE2 Multi-Channel High Speed Counter Module User Manual
Page 33
Advertising
Publication 1746-UM002B-EN-P - August 2004
Module Operation 2-13
Figure 2.8 Count Range with Ring Counter
Range
Start
Value
Stop
Value
Outputs
(1)
(1) Bits 0 through 3 are real outputs. Bits 4 through 7 are virtual outputs.
Outputs
Affected
7
6
5
4
3
2
1
0
1
10,000
12,500
0
0
0
0
0
0
0
1
0
2
200
8,000
0
0
0
0
0
0
1
0
1
3
32,000
500
0
0
0
0
0
1
0
0
2
4
20,000
23,000
0
0
0
0
1
0
0
1
0 and 3
1
32,767
32,000
200
500
8,000
10,000
12,500
20,000
23,000
Range 3
Range 2
Range 4
Range 1
Advertising