Figure 19: fifo sections configuration and signals, Figure 20: fifo sections related signaling – Achronix Speedster22i 10G/40G/100G Ethernet User Manual

Page 44

Advertising
background image

44

UG029, September 6, 2013

The following figure shows the relationship of the configuration values and their respective
signals and levels above and below the levels.

Figure 19: FIFO Sections Configuration and Signals

Figure 20: FIFO Sections Related Signaling

The two signals RX FIFO septy and TX FIFO sav are used internally by the MAC to generate
pause frames and start transmission of frames to the line, respectively.

The other two signals (TX FIFO septy and RX FIFO dsav) are maintained for legacy reasons
only. Note: These signals are not available in this implementation.

rx/tx_section

rx/tx_section_e

dsav

septy

1

0

0

1

RX FIFO

TX FIFO

MAC

TX

RX

ff_rx_dsav

ff_tx_septy

septy

sav

FIFO nearly full

FIFO has at least

one section of data

start transmission

send PAUSE

full indication

FIFO empty

(implicit by dval)

FIFO is full

ff_tx_rdy