1000base-x/sgmii pcs registers description, Table 37, Table 38 – Achronix Speedster22i 10G/40G/100G Ethernet User Manual

Page 73

Advertising
background image

UG029, September 6, 2013

73

1000Base-X/SGMII PCS Registers Description

Table 37

(SGMII PCS) CONTROL Register Description

Bit(s)

Name

Type

Description

0 to 5

Reserved

RO

Read only bit always set to ‘0’.

6 and

13

Speed

Selection

RO

Read only bits that define that the PCS only operates in
Gigabit mode:
Bit 13 set to ‘0’.
Bit 6 set to ‘1’.

7

Collision Test

RO

Half duplex not supported by the PCS, read only bit set to
‘0’.

8

Duplex Mode

RO

Read only bit always set to ‘1’ to indication that the PCS
only supports Full Duplex mode of operation and does not
support Half Duplex mode of operation.

9

Restart Auto

Negotiation

RW

Self-

clearing command bit: Set to ‘1’ to restart an auto

negotiation sequence. Set to ‘0’ (Reset value) in normal
operation mode.

10

Isolate

RW

When set to ‘1’, the PCS is isolated from the MAC Layer
device. Should be set to ‘0’ (Reset value) to enable normal
operation.
Note: When set keeps the PCS in reset (equals bit15=1
permanently).

11

Power Down

RW

When set to ‘1’, the PCS drives its powerdown output pin.
setting not relevant, function not used.

12

Auto

Negotiation

Enable

RW

When set to ‘1’ (Reset value) Auto Negotiation is enabled,
set to ‘0’ to disable Auto Negotiation.

14

Loopback

RW

PHY Loopback Command Register. When set to ‘1’, a
serial loopback is implemented in the PMA. Should be set
to ‘0’ (Reset value) during normal operation.
setting not relevant, function not used.

15

Reset

RW

Self-

Clearing Reset Command Register. When set to ‘1’, a

synchronous reset pulse is generated which resets all the
PCS state machines, the Comma detection function, and
the 8b/10b coder / decoder? ‘0’ for normal operation.

Table 38

(SGMII PCS) STATUS Register Description

Bit(s)

Name

Type

Description

0

Extended

Capability

RO

Read Only bit set to ‘1’ to indicate that the PCS supports
extended registers.

1

Jabber Detect

RO

Read Only bit always set to ‘0’, the PCS does not support
the optional Jabber detection function.

2

Link Status

RO

(LL)

Read Only Link Status Register. When read as a logic
one, indicates that the PCS has determined that a valid
link has been established. When read as a logic zero,
indicates that the link is not valid.
If the link synchronization is lost a ‘0’ is latched which is
cleared only after a register read access.

3

Auto

Negotiation

Ability

RO

Read Only Bit set to ‘1’ to indicate that the PCS PCS
supports Auto-Negotiation.

Advertising