Achronix Speedster22i 10G/40G/100G Ethernet User Manual

Page 63

Advertising
background image

UG029, September 6, 2013

63

20

50

CREDIT_REG

RO

7:0: Current credit register value (for debug
purpose only).
Bits 31:8 are unused and always set to ‘0’.

21

54

CL01_PAUSE_QUANTA

RW

15:0: CL0_PAUSE_QUANTA
31:16: CL1_PAUSE_QUANTA
Value to be sent for the PFC quanta value
for that class when a class XOFF is
triggered.

When normal pause mode is enabled,
CL0_PAUSE_QUANTA is used.

22

58

CL23_PAUSE_QUANTA

RW

15:0: CL2_PAUSE_QUANTA
31:16: CL3_PAUSE_QUANTA
Value to be sent for the PFC quanta value
for that class when a class XOFF is
triggered.

23

5C

CL45_PAUSE_QUANTA

RW

15:0: CL4_PAUSE_QUANTA
31:16: CL5_PAUSE_QUANTA
Value to be sent for the PFC quanta value
for that class when a class XOFF is
triggered.

24

60

CL67_PAUSE_QUANTA

RW

15:0: CL6_PAUSE_QUANTA
31:16: CL7_PAUSE_QUANTA
Value to be sent for the PFC quanta value
for that class when a class XOFF is
triggered.

25

64

CL01_QUANTA_THRES

H

RW

15:0: CL0_QUANTA_THRESH
31:16: CL1_QUANTA_THRESH
When a PFC quanta timer counts down and
reaches this value, a refresh pause frame
should be sent with the programmed full
quanta value if the input level indicates that a
pause condition still exists.

When normal pause mode is enabled,
CL0_QUANTA_THRESH is used for
refreshing pause frames.

26

68

CL23_QUANTA_THRES

H

RW

15:0: CL2_QUANTA_THRESH
31:16: CL3_QUANTA_THRESH
When a PFC quanta timer counts down and
reaches this value, a refresh pause frame
should be sent with the programmed full
quanta value if the input level indicates that a
pause condition still exists.

27

6C

CL45_QUANTA_THRES

H

RW

15:0: CL4_QUANTA_THRESH
31:16: CL5_QUANTA_THRESH
When a PFC quanta timer counts down and
reaches this value, a refresh pause frame
should be sent with the programmed full
quanta value if the input level indicates that a
pause condition still exists.

28

70

CL67_QUANTA_THRES

H

RW

15:0: CL6_QUANTA_THRESH
31:16: CL7_QUANTA_THRESH
When a PFC quanta timer counts down and
reaches this value, a refresh pause frame
should be sent with the programmed full
quanta value if the input level indicates that a

Advertising