Dyno electronics symbols, Dyno electronics symbols -5 – Dynojet WinPEP 7 User Manual

Page 21

Advertising
background image

D Y N O A N D W I N P E P B A S I C S

Dyno Electronics

Version 2

WinPEP 7 User Guide

2-5

D

YNO

E

LECTRONICS

S

YMBOLS

Symbols on the dyno electronics modules help you understand their function.
A description of the module symbols and functions follows.

For more information on connecting your dyno electronics, see “Connecting the
Dyno Electronics” on page 3-11.

symbol

description
Shows when the module is receiving power.

CPU module: the blue LED is lighted when data from

the modules is being acquired and saved.
Input/Output module: the amber LED flashes

proportionally to the dyno drum rpm.
Atmospheric Sensing module: the flashing amber LED

indicates the module processor is operating properly.
Inputs for both primary and secondary inductive

pickup clips. Either input may be used with a primary

or secondary inductive pickup on a single ended coil.

Both inputs can be used for a wasted spark ignition.
Connects to the 25-pin shielded cable from the

dynamometer.

Connects to the 9-pin pendant cable.

Connects to the 9-pin RS-232 PC serial

communications port.

Connects a synchronization signal to a third party data

acquisition system.

Connects a 12 volt DC power to a third party data

acquisition system.

Connects to a 12 volt DC power supply or battery.

The adjacent LED glows bright green when power is

properly connected.
When this switch is on, power is supplied to all

connected modules.

Amber LED flashes at a steady rate when the power is

on; flashes proportionally to the rpm when an rpm

signal is detected, faster rpm equals faster blinking

rate.