C H A P T E R 6
Load Control

6-22

7

Click the Load Control button

to turn on Load Control. You can also use

the letter L on your keyboard.
The yellow indicator light will be on when Load Control is on.
As you approach the Load Control set point, the brake will begin to apply. If you
wish to collect data while in Load Control, you may start sampling.
Note: Load Control will automatically turn off when the run starts if the “Turn Off
Load Control When Run Starts” option is selected. When this feature is off, Load
Control will remain on during the run and the Status Bar on the MakeRun screen
will flash “Sampling. . .” and “Load Control On” alternately. Refer to page 6-5 for
more information.

8

Turn off Load Control by clicking the Load Control button

.

Note: When ending a run with Load Control on, Dynojet recommends using the
brake (red button on your pendant).

Figure 6-20: Load Control

load control button

load control set

point marker

yellow load control

indicator light

selection ring

load control

value edit