Wiring the air valve assembly, Figure 3-19: wire set up 1—terminal strip wiring, Figure 3-20: wire set up 1—breakout board wiring – Dynojet 200: Installation Guide User Manual

Page 43

Advertising
background image

O P T I O N A L A C C E S S O R I E S

Air Brake

Version 3

Motorcycle Dynamometer Installation Guide

3-13

W

IRING

THE

A

IR

V

ALVE

A

SSEMBLY

The wires that attach to the air valve assembly can be attached in two different places
depending on your dyno’s set up. Wire Set Up 1 is generally for older dynos while
Wire Set Up 2 is for newer dynos.

W

IRE

S

ET

U

P

1

This wire set up is used in older dynos that have an exposed (not in a black box)
terminal strip with only eight terminals. If your terminal strip is in a box and has
sixteen terminals, refer to Wire Set Up 2 on page 14.
1

Attach the air hose to the coupler and adjust the regulator to 80 psi.

2

Run the two black wires from the air valve to the top two terminals on the left
side, refer to Figure 3-19.

3

Wire the two black extension leads to the top two terminals on the right side.

Figure 3-19: Wire Set Up 1—Terminal Strip Wiring

4

Remove the four screws securing the Breakout board and cover. Set the screws
and cover aside.

5

Attach the extension leads to the Breakout board. Orientation of the wires is not
important.

6

Replace the Breakout board cover using the four screws removed earlier.

Figure 3-20: Wire Set Up 1—Breakout Board Wiring

black leads from

the air valve

extension leads to

the Breakout board

two black terminal

strip wires

Breakout board

and cover

Advertising