3.4.9 Formulation

Formulations can be named and have from 2 to 10 components
specified. Names are limited to 18 characters. Once named,
they may be recalled and used at any time. Each component
of a given formulation can be specified as to its weight or
percentage. Each element of a formulation is shown on a dual
bar graph as a percentage and displays the desired weight.
Thus, each component may be placed on the pan until 100%
is indicated.

FORMULATION 01/01/03 03:05:45 PM

RESULTS

SETUP

*

0%

50%

90%

110%

100%

Item: 1
Target: 0.00 g
Diff: 00.00 g

Pct:0.00 %

START

0.00

g

Before using the Formulation feature, the Formulation Setup
should be reviewed. Highlight the SETUP soft key and press
the Enter button. Assign a Library Name. Review the settings
and change as necessary. Enter the Mode type, Weight or
Percent. Enter the number of Items.

FORMULATION SETUP

Library Name

:

FORMULATION

Mode

:

Weight

Unit

: g

Number Of Items

: 2

Display Settings

: Default

Items Setup
View Results
Exit

USE

Add the first component to the container. The dual bar graph
at the bottom of the screen indicates the percentage of the
component added. The target weight, difference and percent
are also displayed. Add each component until the specified
Target weight is reached (100%). When adding an individual
component, make sure the balance has stabilized and indicates
the specified weight. Continue until all components have been
added.

The next screen automatically appears and indicates the Target,
Result and Difference weights of each component of the formula
as well as the totals. Pressing the PRINT button will send the
screen results to an externally connected printer or computer.

Press the Enter button to exit and return to the starting screen.
Results of any formulation may be displayed by selecting the
RESULTS soft key at the top of the screen. The actual formulation
is selected by entering the FORMULA SETUP screen and scrolling
through the Library Names.

To start a new formulation, repeat the entire process.

ADJUSTMENTS

START/ACCEPT
When the START key is selected, pressing the Enter button will
start formulation application. The screen displays “Add Item
“name field”, Press Enter” message and the Formulation process
has started. When a new process starts, all the data from
previous Formulation is erased. At this point, the soft key has
changed into an ACCEPT key. When the ACCEPT key is selected,
the weight value has been accepted as valid data.

SETUP
When selected, the FORMULA SETUP screen will be displayed.

RESULTS
When selected, a screen will display all calculated results.

Library Name:
Allows storage and recovery of parameters and results.
When a library is recovered, the library name will replace the
application name in the application mode screen. The library
name has maximum of 18 characters.

Exit the Formulation Setup. The initial screen appears with the
name of the formulation appearing at the upper left-hand corner
of the screen.

Place a container on the pan and press the >O/T< button to
tare the container weight.

With the START key highlighted, press the Enter button. Follow
the instructions on the screen. The START key changes to ACCEPT.