Measure new sample alignment value, Use stored sample alignment value – Aviom 6416m/RCI/MCS User Manual

Page 115

Advertising
background image

104

A

dvAnced

F

unctions

ChannEl

11 a

CtivE

button. Press

E

ntEr

; the A‑Net Slot display is used to

indicate the current value in use.

The A‑Net Slot display reads “0” to indicate that the system’s

default values are being used. (This is set with Function

14.)
The A‑Net Slot display reads “1” to indicate that stored

values are being used. (This is set with Function 13.)

Measure New Sample Alignment Value

To generate a new sample alignment value, use Function 12. This Function

can only be performed at the Control Master when the network is unlocked.

Press the

F

unCtion

button, followed by

ChannEl

12 a

CtivE

button. The sixteen

channel meter LEDs and the Enter/Cancel LED will flash, indicating that this

operation will replace the currently stored value. Press

E

ntEr

to measure

and generate a new sample alignment value, or press

C

anCEl

to exit without

updating the stored value. A forward sweep of the level LEDs indicates that

the function is complete.

Values are stored in each module’s memory but are not put into use until

Function 13 (Use Stored Sample Alignment Values) is performed, which

activates the stored sample alignment values. The module must be the

network Control Master to use its stored value. Use Function 11 to get info on

the current values in use.

When the stored sample alignment value is being used, a new sample

alignment value should be calculated each time the network sample rate is

changed, or when the system configuration changes. (Changes include the

addition/subtraction of Pro64 modules, different wiring schemes, etc.)

Use Stored Sample Alignment Value

When a new sample alignment value has been generated and stored,

Function 13 can be used to activate and lock in this value for use throughout

the network. This Function can only be performed at the Control Master

when the network is unlocked.

To use the stored value, press the

F

unCtion

button, followed by the

ChannEl

13

aCtivE

button. The Enter/Cancel LED and the sixteen yellow channel meter

LEDs will flash. Press

E

ntEr

to use the stored value, or press

C

anCEl

to exit

without changing the sample alignment value (the system reverts to using

the default value).

The stored sample alignment value remains in force even when the network

is power cycled. When the network is reconfigured or when the sample rate

is changed, a new value should be calculated using Function 12 described

above.