Rci rear panel features, Ac power, Fuse – Aviom 6416m/RCI/MCS User Manual

Page 84: Backup dc power, Remote control interface

Advertising
background image

73

rci F

ront

P

Anel

F

eAtures

RCI Rear Panel Features

All RCI rear‑panel features and functions are described in this section.

AC Power

Pro64 modules use switching power supplies that can operate at 100‑240V

and from 50‑60Hz, meaning that they can be used with most of the world’s

AC power systems by simply changing the line cord. The RCI is equipped

with a standard grounded IEC power inlet (with fuse), which can accept the

interchangeable IEC power cord.

Fuse

The fuse holder is spring‑loaded and has space for two fuses, one main and

one spare (optional). Press the fuse holder cover to access the fuse. When

checking or replacing a fuse, always power off the Pro64 unit and remove the

line cord from the AC power source.

Always replace the fuse with one of the same rating as that being changed.

Backup DC Power

For applications where a backup power source is required, the RCI is

equipped with a backup DC power inlet using a locking 4‑pin XLR jack. A DC

power supply capable of outputting 24VDC ±5% at 0.75 amp is required. In

the locking XLR plug, connect pin 1 to ground and pin 4 to the 24VDC supply.

Nothing should be connected to pins 2 and 3.

PAD

0.75 AMP

BACKUP POWER

PIN 1 = GND

PIN 4 = 24VDC

AC POWER

FUSE: 250VAC-F4AL

Remote Control Interface

RCI

B

A

+4dBu LINE�LEVEL OUTPUT �BAL�

PIN 2 HOT

The RCI can be powered via its internal power supply or an optional external

24 volt supply.

Both internal AC and external DC power sources can be connected

simultaneously. The AC Power switch only controls the AC inlet.