Managed Button

The Managed button is used to put the network under control of a computer

for firmware updates, system monitoring, etc. Managed Mode can only be

engaged from the network’s Control Master.

When using a PC for firmware updates, etc., a Pro64 module cannot have

its RS‑232/422 or MIDI port assigned to a VDC when the PC is connected.

Deactivate these VDC assignments before entering Managed Mode.

Connecting a PC to the Control Master requires the use of the RS‑232 port for

communication. The RS‑232 baud rate DIP switches also need to be set to the

same rate as the computer application for data transfers.

To enter Managed Mode, press the

M

anagEd

button; its LED will flash. The

Enter/Cancel LED will also flash. Press

E

ntEr

to confirm the mode change or

C

anCEl

to return to the previous state.

To exit Managed Mode, press the

M

anagEd

button; its LED will flash and the

Enter/Cancel LED will flash. Press

E

ntEr

to confirm the mode change. The

network returns to the previous local mode, Auto or Manual.

In Managed Mode, Virtual Data Cable and channel Active buttons behave as

if the module is edit locked; they provide information only when pressed. All

other front panel edits are prohibited.

Edit Lock Button

The front panel of the 6416m can be locked to prevent accidental changes

or low‑level unauthorized access. Once edit locked, all front‑panel functions

under digital control cannot be changed. Edit Lock can be used on a module‑

by‑module basis.

To lock a module’s front panel, press the

E

dit

l

oCk

button. The Enter/Cancel

LED will blink. Press

E

ntEr

to lock the unit. No other Pro64 modules in the

network are affected. Press the

C

anCEl

button to exit the operation without

locking the device’s front panel.

To unlock a Pro64 device, press the

E

dit

l

oCk

button again. The Enter/Cancel

LED will blink. Press the

E

ntEr

button to unlock the unit. Press

C

anCEl

to exit,

leaving the unit locked.

When a Pro64 module is edit locked, all front panel operations are inactive

with the following exceptions:

The Edit Lock button, along with the Enter button,

can be

used to unlock the unit.

• Gain switches on I/O modules such as the 6416i are analog

controls. These cannot be locked.
Channel

Active buttons can be used to get information