Rs-232 configuration dip switches, Rs-232 baud rates – Aviom 6416m/RCI/MCS User Manual

Page 74

Advertising
background image

63

v

irtuAl

d

AtA

c

Ables

VIRTUAL DATA CABLE PORTS

AC POWER

FUSE: 250VAC-F4AL

IN

OUT

1 2 3 4

1

2

3

4

RS-232
RESERVED
CONTROL MASTER

1–8

9

10

IN

OUT

ON

RS-232

1.75 AMP

PIN 1 = GND

PIN 4 = 24VDC

BACKUP POWER

GPIO INPUT

UP = ISOLATED
DN = TTL

9–16 THRU (ALT. IN)

1–8 THRU (ALT. IN)

Mic/Line Inputs (Bal) Pin 2 Hot

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

Mic Input Module

B

A

The first eight switches on the DIP switch block are used to set the RS-232

baud rate.

The RS‑232 port is also used for computer communication with Pro64 devices

for firmware updates and other Managed Mode applications.

The RS‑232 port on the 6416m uses a 9‑pin DB9 connector and eight of the ten DIP

switches in the DIP switch block (the remainder are used for system functions).

RS-232 Configuration DIP Switches

RS‑232 communication is configured using the first eight switches in the DIP

switch block. Switches 1‑4 set the baud rate and switches 5‑8 are used to set

data, parity, and stop bit options. Switches 9 and 10 are reserved for system

use.

Switch

Function

Off

On

1

Baud Rate bit 3

See Baud Rate chart

2

Baud Rate bit 2

3

Baud Rate bit 1

4

Baud Rate bit 0

5

Data Bits

7

8

6

Parity Low/High

No parity

Parity

7

Parity Even/Odd

Even

Odd

8

Stop Bit

1

2

9

Reserved

10

Control Master

To set a DIP switch to the

o

n

position, push it upwards.

RS-232 Baud Rates

To set a baud rate, determine the appropriate baud rate for data transfer

by referring to the external send/receive devices’ documentation. Set both

devices to communicate using the same baud rate. Finally, set the Pro64

devices to the same baud rate and activate the VDCs using the front‑panel

interface.