Changing the a-net transmit port, Clock master, Sample rate – Aviom 6416m/RCI/MCS User Manual

Page 48: Changing the a‑net transmit port, Clock master sample rate

Advertising
background image

37

n

etwork

s

ettings

6416

m

A-NET SLOT

Edit Lock

Managed

Edit

CONTROL

MASTER

ENTER

CANCEL

Gain

(dB)

Port A

Port B

Auto

A-NET

TRANSMIT

Manual

VDC SLOT

RS-232

MIDI In

MIDI Out

GPIO In

GPIO Out

ASSIGN

PORT

CLOCK

MASTER

CONTROL

Sample Rate

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

Link

Link

Link

Link

Link

Link

Link

Link

Mute

Edit

Mute

Edit

Mute

+48V

Phase

Low Cut

SAVE

RECALL

Pad

Ø

Pad

+48V

Ø

Pad

+48V

Ø

Pad

+48V

Ø

Pad

+48V

Ø

Pad

+48V

Ø

Pad

+48V

Ø

Pad

+48V

Ø

Pad

+48V

Edit

Mute

Edit

Mute

Edit

Mute

Edit

Mute

Edit

Mute

Edit

Mute

Edit

Mute

Mute

Mute

Mute

Edit

Edit

Edit

Edit

Mute

Edit

Mute

Edit

Mute

FUNCTION

Group 4

Group 3

Group 2

A-Net data is set to transmit out

of Port B in Manual Mode in this

example.

Changing the A-Net Transmit Port

This applies to Manual Mode only; no user settings are available in Auto

Mode.

Use the selector button below the Auto/Manual Mode LED readout to cycle

through the three options. When a new configuration is selected, the selected

Port LED and the Enter/Cancel LED will blink; confirmation is required. Press

E

ntEr

to set a new transmit Port or press

C

anCEl

to exit without making a

change and return to the previous setting.

Changing the transmit Port settings in Manual Mode has no effect on the

current channel activation settings. The VDCs are not affected by the

network mode.

Clock Master

One device in a Pro64 network will always be set as the network’s Clock

Master. In a network with only analog I/O modules, the module set as the

Control Master is also set to be the Clock Master by default. The Module set

as the Clock Master will have its Clock Master LED lit.

When digital I/O modules are used in a network, incoming Word Clock or

AES3 (also referred to as AES/EBU) digital data streams can also be used as

clock sources. It is only when a digital module is part of the network that the

Control Master and Clock Master can be separate devices.

Set the 6416m to be the network Control Master using DIP switch #10, found

on the rear panel.

Sample Rate

Pro64 networks can operate at sample rates in three ranges without the use

of sample rate converters. The current network sample rate also determines

the number of available A‑Net Slots.