56

6416

M

r

eAr

P

Anel

F

eAtures

6416m Rear Panel Features

All 6416m rear‑panel features and functions are described in this section.

AC Power

Pro64 modules use switching power supplies that can operate at 100‑240V

and from 50‑60Hz, meaning that they can be used with most of the world’s

AC power systems by simply changing the line cord. The 6416m is equipped

with a standard grounded IEC power inlet (with fuse), which can accept the

interchangeable IEC power cord.

Fuse

The fuse holder is spring‑loaded and has space for two fuses, one main and

one spare (optional). Press the fuse holder cover to access the fuse. When

checking or replacing a fuse, always power off the Pro64 unit and remove the

line cord from the AC power source.

Always replace the fuse with one with the same rating as that being

changed.

Backup DC Power

For applications where a backup power source is required, the 6416m is

equipped with a DC power inlet using a locking 4‑pin XLR jack. A DC power

supply capable of outputting 24VDC ±5% at 1.75 amps is required. In the

locking XLR plug, connect pin 1 to ground and pin 4 to the 24VDC source.

Nothing should be connected to pins 2 and 3.

VIRTUAL DATA CABLE PORTS

AC POWER

FUSE: 250VAC-F4AL

IN

OUT

1 2 3 4

1

2

3

4

RS-232
RESERVED
CONTROL MASTER

1–8

9

10

IN

OUT

ON

RS-232

1.75 AMP

PIN 1 = GND

PIN 4 = 24VDC

BACKUP POWER

GPIO INPUT

UP = ISOLATED
DN = TTL

9–16 THRU (ALT. IN)

1–8 THRU (ALT. IN)

Mic/Line Inputs (Bal) Pin 2 Hot

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

Mic Input Module

B

A

The 6416m can be powered via its internal power supply or an optional

external 24 volt supply.

6416m DC Requirements

Like most electronic devices, the 6416m will draw more than its rated current