CHAPTER 2 - SPECIFICATIONS

2-1

CHAPTER 2 - SPECIFICATIONS

SCOPE

Chapter 2 lists the specifications of the HI
200DNWM weigh module. Specifications
are listed for the standard module and
optional equipment. The specifications listed
are designed to assist in the installation,
operation and troubleshooting of the module.
All service personnel should be familiar with
this chapter before attempting an installation
or repair of the instrument.

Conversion Rate

10 updates per second (When WAVER-
SAVER is turned OFF or set to 1= 55
updates per second)

Resolution

20 bits

Excitation Voltage

0-5 VDC

Averages

1 to 255 User Selectable in Single Incre-
ments.

Load Sensors

Up to eight (8) 350 ohm Full Wheatstone
Bridge, Strain Gauge Load Sensors/Cells (5
volt excitation) on one vessel. Using more
than 4 load cells requires an external power
supply.

Non-Linearity

0.0015% of Full Scale

Isolation

Non Isolated, uses external solid state relays
for set points.

Voltage

Input power - Power from DeviceNet Cable

24 VDC +/- 1% Network

11-25 VDC Node