Setpoint mode parameters -12, Hi 200dnwm manual – Hardy HI 200DNWM DeviceNet Weigh Module User Manual

Page 46

Advertising
background image

HI 200DNWM MANUAL

5-12

using. Be sure to read the DeviceNet Man-
ager instructions first before setting.

Setpoint Mode
Parameters

About
Setpoint
Mode
Parameter

The Setpoint mode parameter is a bit
encoded byte that affects the behavior of the
setpoint.

Entering
Setpoint
Mode
Parameters

Bit

Description

Bit 7

Setpoint On/Off. Set to 1 to activate the setpoint, set
to 0 to disable it.

Bit 6

Set to 1 to output 0 volts (Force Relay Off)

Bit 5

Set to 1 to output 5 volts (Force Relay On)

Bit 1

Set to 0 for a gain in weight setpoint, set to 1 for a loss
in weight setpoint.

Bit 0

Set to 1 for a setpoint based on Net weight, or to 0 for
a setpoint based on gross weight.