HI 200DNWM MANUAL

5-2

SAVER

®

” for example, the SAVE request

should be sent BEFORE cycling the power.

The non-volatile RAM has a maximum of
5,000,000 writes.

Parameters

Parameter 1 = Metric Poll
True = kgs net

False = lbs net

Length in Bytes = 1

NOTE:

Default settings are indicated by bold type.

Parameter 2 = WAVERSAVER

®

Setting

0 =OFF 1 = 4 Hz, 2 = 2Hz, 3 = 1.0 Hz, 4
= 1/2 Hz
Length in Bytes = 1

NOTE:

By selecting OFF (0) or 1 the module increases the
updates per second from 10 to 55.

Parameter 3 = Calibration Type
0 = Hard Cal, 1 = C2 Cal, Other = Not
Cal’d (Read Only)
Length in Bytes = 1

Parameter 4 = Span Weight in Lbs
1 to 2147483647 10000.000
Length in Bytes = 4

Parameter 5 = Averages
0 to 255 10
Length in Bytes = 1

Parameter 6 = Set Point One Mode
bit 7 = On/Off bit 1 = Low/High
bit 0 = Net/Gross
Length in Bytes = 1