Module status (ds2) -3, Chapter 7 - operation, Module status (ds2) – Hardy HI 200DNWM DeviceNet Weigh Module User Manual

Page 53

Advertising
background image

CHAPTER 7 - OPERATION

7-3

Module Status
(DS2)

Table 7-2: MODULE STATUS (DS2)

OPERATION
AND ON LINE
NOT CON-
NECTED

FLASHING
GREEN

ON LINE NORMAL CONDITION NO CONNECTIONS
Dup_MAC_ID PASSED & ON LINE, NO CONNECTIONS
TO OTHER NODES.

CRITICAL
FAULT OR LINK
FAILURE

RED

UNRECOVERABLE FAULT (MAY NEED REPLACING)
FAILED COMMUICATIONS (DUPLICATE Mac ID OR BUS
OFF)

STATE

LED

INDICATION

Table 7-1: NETWORK STATUS (DS1)

STATE

LED

INDICATION

NOT POWERED/
NOT ON LINE

OFF

DEVICE IS NOT ON LINE
1. NO POWER APPLIED

OPERATIONAL

GREEN

NORMAL CONDITION

MINOR FAULT
AND/OR CON-
NECTION TIME-
OUT

FLASHING
RED

RECOVERABLE FAULT A/D ERROR, USUALLY
CAUSED BY BAD CONNECTION TO LOAD CELLS
LOAD CELL OUT OF RANGE. SENSE LINES MUST BE
INSTALLED. (See Chapter 3, Page 3-10 for more information)

CRITICAL
FAULT OR LINK
FAILURE

RED

UNRECOVERABLE FAULT (Board MAY NEED REPLAC-
ING)
FAILURE IN A-D.

Advertising