CHAPTER 4 - CONFIGURATION

4-1

CHAPTER 4 - CONFIGURATION

SCOPE

Chapter Four consists of all the proce-
dures for configuring the HI 200DNWM
Weigh Module. System configuration
includes only hardware adjustments such
as Jumper and Dip Switch settings. We
recommend that maintenance personnel
be familiar with this chapter before con-
figuring the Weigh Module. Alternative
configuration procedures are not recom-
mended.

Differences in the
Series A and Series B
Modules

The Series B 200 DNWM module uses 4
bytes of input polled data. This requires
each module to use a different .EDS file.

Changing from the
Series A to the
Series B Module

Configuration when using RS NetWorx
for DeviceNet require the new .EDS file.
This adds the 4 bytes of input polled
data. If you want to use the new features
of the module, the 4 bytes of input polled
data need to be mapped into the scan-
ner’s scanlist.
If you do not map the input polled data
into the scanner’s scanlist, the module
will operate as if it were a Series A. No
changes need to be made to any ladder
logic written for the module.

Changing from the
Series B to the
Series A Module

If you change from Series B to the older
module, the configuration when using
RS NetWorx for DeviceNet needs to be
done using the older .EDS file. This will
remove the 4 bytes of input polled data.
These 4 bytes of data must then be
removed from the scanner’s scanlist. All