Monitoring weight readings from rs networx -2, Network status (ds1) -2 – Hardy HI 200DNWM DeviceNet Weigh Module User Manual

Page 52

Advertising
background image

HI 200DNWM MANUAL

7-2

can be found in the HI 200DNWM
WEIGH MODULE I&O manual.

ATTRIBUTE: The parameter value
attribute number is 1.

DATA: (varies)

NOTE:

Data length can vary, be sure to enter the correct
length (size) of data or problems will occur.

NOTE:

Order of bytes must be least significant first.

Monitoring Weight
Readings from RS
NetWorx

Step 1. On the PC open RS NetWorx.
Step 2. Browse the Network.
Step 3. Double click on the Node Icon of

the weigh module you want to
monitor. For example: Node 36.
The DeviceNet Weigh Module Dia-
log Box appears for Node 36.

Step 4. Click on the Parameters Tab.
Step 5. All the parameters including the

weights are displayed.

Step 6. The NET, GROSS, and TARE

weights are now being monitored.

NOTE:

The HI 200DNWM can be used for Batching, Filling,
Dispensing, and Check Weighing applications.

Network Status
(DS1)

STATE

LED

INDICATION

NOT POWERED/
NOT ON LINE

OFF

DEVICE IS NOT ON LINE
1. NO POWER APPLIED
2. Dup_MAC_ID TEST NOT COMPLETE

OPERATIONAL
AND ON-LINE

GREEN

ON LINE NORMAL CONDITION WITH CONNECTIONS
ESTABLISHED.

Table 7-1: NETWORK STATUS (DS1)