10 - Connect the Power and Ground

RocketLinx ES7510-XT User Guide: 2000571

Rev. D

Hardware Installation

• PWR1 and PWR2 support power redundancy and reverse polarity protection.

• Accepts a positive or negative power source but PWR1 and PWR2 must apply to the same mode.

• If both power inputs are connected, the ES7510-XT is powered from the highest connected voltage.

• The ES7510-XT can emit an alarm if PWR1 or PWR2 are no longer receiving power. See the

Warning

discussion on

Page 117

to configure an alarm.

2.

Connect a ground wire between the chassis and earth ground using
12-24AWG wire to ensure that the ES7510-XT is not damaged by
noise or electrical shock.

a.

Loosen the chassis ground screw on the bottom of the ES7510-
XT.

b.

Insert the ground wire.

c.

Tighten the ground screw after the earth ground wire is
connected.

ELectrical Specifications

Value

Power Input

Voltage DC1/DC2

IEEE 802.3af

46-57VDC

IEEE 802.3at

50-57VDC

Maximum PoE

Power/Port

IEEE 802.3af

15.4W

IEEE 802.3at

30W

Power Budget

DC1/DC2

120W

Power

Consumption

Without PD
load (maximum)

15W

PoE with PD
load (maximum)

140W