120 - SysLog Configuration

RocketLinx ES7510-XT User Guide: 2000571

Rev. D

Configuration Using the Web Interface

SysLog Configuration

The System Log provides the system administrator ES7510-XT events history. There are two System Log
modes provided by the ES7510-XT, Local mode and Remote mode.

When enabling Local or Both modes, you can monitor the system logs in the Monitor and Diag /Event Log
page.

Port Event

Warning is sent when…..

Link-Up

The port is connected to another device.

Link-Down

The port is disconnected. For example, the cable is pulled out or the opposing
devices is down.

Both

The link status changed.

PoE Powering Event

Warning is sent when…..

Enable

The PoE port is powering.

Disable

The PoE port is not powering.

Apply

Click Apply to apply the settings.

Note: You must Save the settings (

Page 130

), if you want to maintain these

settings if the ES7510-XT is powered off.

Warning - SysLog Configuration Page

Syslog Mode

There are two system logs available:

Local Mode: The ES7510-XT prints the events that have been
selected in the Event Selection page to the System Log table of
the ES7510-XT. You can monitor the system logs in the
Monitor and Diag /Event Log page.

Remote Mode: Assign the IP address of the System Log server

.

The ES7510-XT sends the events that occurred in the selected
in Event Selection page to System Log server that you assign.

Both: This enables both Local and Remote modes.

Remote IP Address

The IP address of the System log server.

Apply

Click Apply to apply the settings.

Note: You must Save the settings (

Page 130

), if you want to

maintain these settings if the ES7510-XT is powered off.