Configuration Using the Web Interface

Warning

The ES7510-XT provides several types of warning features for you to remotely monitor the status of the
attached devices or changes in your network. The features include System Log and SMTP Email Alert.

The following web pages are included in this group:

Fault Relay

Event Selection

on Page 119

SysLog Configuration

on Page 120

SMTP Configuration

on Page 121

Optionally, you can use the CLI for configuration, see

Warnings (CLI)

on Page 184.

Fault Relay

The ES7510-XT provides one alarm relay output (DO) that can support multiple fault conditions. The relay
contacts are energized (open) for normal operation and close under fault conditions. The fault conditions
include power failure, Ethernet port link faults, Ring topology changes, Ping failures, DI state changes or ping
remote IP address failure.

The Relay 1 field shows the current state of the relay. If the relay is triggered, the event type is marked with
an asterisk (*). The above image shows that a power event occurred.

The following table describes Fault Relay conditions:

Fault Relay

Power

Detects power input status on DC1, DC2, or both power sources.

Port Link

Monitors port link down events for the selected ports.

Ring

Monitors ring topology changes.

Ping

If the target IP address does not reply to the ping request, the fault relay
is enabled.

Ping Reset

Pings target device and triggers the relay to emulate to emulate a power
reset on the remote device if the remote system crashes.

IP Address: Remote device IP address whose power wiring is

connected

with relay output.

Reset Time (Sec): Duration that the relay contact is opened to emulate
the power switch is off. After the reset time, the relay closes to
emulate that the power switch is on.

Hold Time (Sec): Boot time that the remote device requires. After the
relay contact closes the ES7510-XT starts pinging after the hold time.