Hardware installation, Connect the power and ground – Comtrol ES7510-XT User Manual

Page 9

Advertising
background image

RocketLinx ES7510-XT User Guide: 2000571

Rev. D

Connect the Power and Ground - 9

Hardware Installation

You can use the following subsections to install the RocketLinx ES7510-XT:

Connect the Power and Ground

Connect the Digital Inputs and Relay Outputs

on Page 11

Mount the ES7510-XT

on Page 12

Connect the Ethernet Ports

on Page 13

Connect SFP Transceivers (Combo Ports 9-10)

on Page 14

LED Descriptions

on Page 14

Reset Button

on Page 15

Connect the Power and Ground

You can use the following procedure to connect power and the ground to the ES7510-XT.

1.

Connect the DC power inputs.

a.

Insert positive and negative wires (12-24AWG) into the PWR+ and PWR- contacts.

Note: Power should be disconnected from the power supply before connecting it to the switch.

Otherwise, your screw driver blade can inadvertently short your terminal connections to the
grounded enclosure.

b.

Tighten the wire-clamp screws to prevent the wires from coming loose.

AC Power Input

AC Power Input

Power Supply

46- 57VDC

(UL Listed)

Power Supply

46-57VDC

(UL Listed)

V+

V-

V+

V-

12 - 24AWG Wire

12 - 24AWG Wire

Wiring Positive Power Supplies

Positive and negative power system inputs are both accepted, but
PW1 and PW2 must be in the same mode.

Advertising