Comtrol ES7510-XT User Manual

Page 165

Advertising
background image

166 - Network Redundancy (CLI)

RocketLinx ES7510-XT User Guide: 2000571

Rev. D

Configuration Using the Command Line Interface (CLI)

Redundant Ring

Create or
configure a Ring

Switch(config)# redundant-ring 1

Ring 1 created

Switch(config-redundant-ring)#

Note: 1 is the target Ring ID which is going to be created or configured.

Super Ring
Version

Switch(config-redundant-ring)# version

default

set default to Redundant ring

rapid-super-ring rapid super ring

super-ring

super ring

Switch(config-redundant-ring)# version rapid-super-ring

Priority

Switch(config-redundant-ring)# priority

<0-255> valid range is 0 to 255

default set default

Switch(config-redundant-ring)# super-ring priority 100

Ring Port

Switch(config-redundant-ring)# port

IFLIST Interface list, ex: fa1,fa3-5

cost path cost

Switch(config-redundant-ring)# port fa1,fa2

Ring Port Cost

Switch(config-redundant-ring)# port cost

<0-255> valid range is 0 or 255

default set default (128)valid range is 0 or 255

Switch(config-redundant-ring)# port cost 100

<0-255> valid range is 0 or 255

default set default (128)valid range is 0 or 255

Switch(config-redundant-ring)# port cost 100 200

Set path cost success.

Rapid Dual
Homing

Switch(config-redundant-ring)# rapid-dual-homing enable

Switch(config-redundant-ring)# rapid-dual-homing disable

Switch(config-redundant-ring)# rapid-dual-homing port

IFLIST Interface name, ex: fa1

auto-detect Uplink auto detection

IFNAME Interface name, ex: fa1

Switch(config-redundant-ring)# rapid-dual-homing port 3,5-6

set Rapid Dual Homing port success.

Note: Auto-detect is recommended for Dual Homing.

Advertising