12 - Connect the Surge/Lightening Protection

RocketLinx ES7510-XT User Guide: 2000571

Rev. D

Hardware Installation

Connect the Surge/Lightening Protection

Connect a ground wire between the earth ground (surge) screw and earth ground to
provide enhanced surge and lighting immunity.

1.

Loosen the earth ground screw located on the back of the unit next to the
compliance label.

2.

Insert the ground wire (12-24AQWG).

3.

Tighten the surge screw after the ground wire is inserted.

Make sure that you remove the surge ground screw before insulation/Hi-pot testing.

Mount the ES7510-XT

You can use the following procedure to mount the ES7510-XT on a DIN rail or on the wall.The DIN rail clip is
already attached to the ES7510-XT. If the DIN rail clip is not screwed onto the ES7510-XT, follow the
instructions and the figure below to attach DIN rail clip to the ES7510-XT.

1.

If necessary, use the screws to attach DIN rail clip to the rear
panel of the ES7510-XT. (To remove DIN rail clip, reverse Step 1.)

2.

Insert the upper end of DIN rail clip into the back of DIN rail
track from its upper side.

3.

Lightly push the bottom of DIN rail clip into the track.

4.

Verify that the DIN rail clip is tightly attached on the track.

5.

To remove the ES7510-XT from the track, reverse the steps above.

DIN Rail Mounting

Follow the steps below to install the ES7510-XT with the wall mounting plate:

1.

To remove the DIN rail clip from the ES7510-XT, loosen the screws from the DIN rail
clip.

2.

Place the wall mounting plate on the rear panel of the ES7510-XT.

3.

Use the screws to attach the wall mounting plate to the ES7510-XT.

4.

Use the hook holes at the corners of the wall mounting plate to hang the ES7510-XT
onto the wall.

5.

To remove the wall mounting plate, reverse the steps above.

Wall Mount Installation