Comtrol ES8510-XT User Manual

Page 127

Advertising
background image

RocketLinx ES8510 and ES8510-XT User Guide: 2000513 Rev. H

Using the Serial Console - 127

Configuration Using the Command Line Interface (CLI)

HyperTerminal (Windows XP, unless installed manually)

-

Windows XP: Go to Start -> Program -> Accessories -> Communications -> HyperTerminal

-

Enter a name for the new console connection and click OK.

-

Enter the IP address in the Host Address text box.

-

Select TCP/IP (Winsock) in the Connect using drop-list and click Ok.

-

Set the serial settings using the

Serial Settings

table (above).

-

Press the Enter key in the Terminal window.

-

After it is connected, you can see the Switch login request, go to

Step 3

3.

Log in to the switch. The default user name is admin, password, admin.

4.

If necessary, configure the IP address for your network. The following example shows how to program an
IP address of 192.168.11.252 with a Class B subnet mask (255.255.0.0).

Switch login: admin

Password:

Switch (version 2.4a-20110930-09:49:48).

Switch>

Switch> enable

Switch# configure terminal

Switch(config)# int vlan1

Switch(config-if)# ip address 192.168.11.252/16

Advertising