Comtrol ES8510-XT User Manual

Page 145

Advertising
background image

RocketLinx ES8510 and ES8510-XT User Guide: 2000513 Rev. H

Port Configuration (CLI) - 145

Configuration Using the Command Line Interface (CLI)

Port Control (continued)

Port Control
– Flow
Control

Switch(config-if)# flowcontrol on

Flowcontrol on for port 1 set ok!

Switch(config-if)# flowcontrol off

Flowcontrol off for port 1 set ok!

Port Status

Switch# show interface fa1

Interface fastethernet1

Administrative Status : Enable

Operating Status : Connected

Duplex : Full

Speed : 100

Flow Control :off

Default Port VLAN ID: 1

Ingress Filtering : Disabled

Acceptable Frame Type : All

Port Security : Disabled

Auto Negotiation : Disable

Loopback Mode : None

STP Status: forwarding

Default CoS Value for untagged packets is 0.

Mdix mode is Disable.

Medium mode is Copper.

Switch# show sfp ddm

show SFP DDM information

Port 8

Temperature:N/A

Tx power:N/A

Rx power:N/A

Port 9

Temperature:64.00 C <range :0.0-80.00>

Tx power:-6.0 dBm <range : -9.0 - -4.0>

Rx power:-30.0 dBm <range: -30.0 - -4.0>

Port 10

Temperature:67.00 C <range :0.0-80.00>

Tx power:-6.0 dBm <range : -9.0 - -4.0>

Rx power:-2.0 dBm <range: -30.0 - -4.0>

Note: Administrative Status -> Port state of the port. Operating status -> Current status of the

port. Duplex -> Duplex mode of the port. Speed -> Speed mode of the port. Flow control -
> Flow Control status of the port.